arrow_back_ios

Main Menu

See All Acoustic End-of-Line Test Systems See All DAQ and instruments See All Electroacoustics See All Software See All Transducers See All Vibration Testing Equipment See All Academy See All Resource Center See All Applications See All Industries See All Insights See All Services See All Support See All Our Business See All Our History See All Our Sustainability Commitment See All Global Presence
arrow_back_ios

Main Menu

See All Actuators See All Combustion Engines See All Durability See All eDrive See All Transmission & Gearboxes See All Turbo Charger See All DAQ Systems See All High Precision and Calibration Systems See All Industrial electronics See All Power Analyser See All S&V Hand-held devices See All S&V Signal conditioner See All Accessories See All DAQ Software See All Drivers & API See All nCode - Durability and Fatigue Analysis See All ReliaSoft - Reliability Analysis and Management See All Test Data Management See All Utility See All Vibration Control See All Acoustic See All Current / voltage See All Displacement See All Load Cells See All Pressure See All Strain Gauges See All Torque See All Vibration See All LDS Shaker Systems See All Power Amplifiers See All Vibration Controllers See All Accessories for Vibration Testing Equipment See All Training Courses See All Whitepapers See All Acoustics See All Asset & Process Monitoring See All Custom Sensors See All Data Acquisition & Analysis See All Durability & Fatigue See All Electric Power Testing See All NVH See All Reliability See All Smart Sensors See All Vibration See All Weighing See All Automotive & Ground Transportation See All Calibration See All Installation, Maintenance & Repair See All Support Brüel & Kjær See All Release Notes See All Compliance See All Our People
arrow_back_ios

Main Menu

See All CANHEAD See All GenHS See All LAN-XI See All MGCplus See All Optical Interrogators See All QuantumX See All SomatXR See All Fusion-LN See All Accessories See All Hand-held Software See All Accessories See All BK Connect / Pulse See All API See All Microphone Sets See All Microphone Cartridges See All Acoustic Calibrators See All Special Microphones See All Microphone Pre-amplifiers See All Sound Sources See All Accessories for acoustic transducers See All Experimental testing See All Transducer Manufacturing (OEM) See All Accessories See All Non-rotating (calibration) See All Rotating See All CCLD (IEPE) accelerometers See All Charge Accelerometers See All Impulse hammers / impedance heads See All Cables See All Accessories See All Electroacoustics See All Noise Source Identification See All Environmental Noise See All Sound Power and Sound Pressure See All Noise Certification See All Industrial Process Control See All Structural Health Monitoring See All Electrical Devices Testing See All Electrical Systems Testing See All Grid Testing See All High-Voltage Testing See All Vibration Testing with Electrodynamic Shakers See All Structural Dynamics See All Machine Analysis and Diagnostics See All Process Weighing See All Calibration Services for Transducers See All Calibration Services for Handheld Instruments See All Calibration Services for Instruments & DAQ See All On-Site Calibration See All Resources See All Software License Management

Software and solutions for durability, fatigue, and reliability engineering professionals

Unique and integrated approach for product test, design and maintenance optimization

Durability testing, reliability, and failure mode comparison

Let’s assume you are an engineer tasked with validating the durability of a structural part that is susceptible to fatigue cracking. Proving ground tests are often used to assess component durability, but unfortunately they can be costly and time consuming. A laboratory durability test is desirable due to reduced variability, cost, and time but you then face the challenge of moving the durability test into the lab while replicating the same failure behavior.  

If fatigue is the failure mode, fatigue methodologies like Stress-Life (SN) can be used to create an equivalent fatigue damage test specification. This way, the complicated loading seen on the proving ground can be converted into simplified test lab loading that produces the same amount of fatigue damage. Once a relative damage relationship has been determined, the lab test can be run and results from the proving ground and lab can be compared statistically with reliability methods to assess the failure behavior and answer these critical questions:  

  • Are these failure modes the same? 
  • Is the lab test representative of real product usage? 

This process can be performed in three general steps:

Step 1: Assessing fatigue cyclic content

The structural loading this part experiences in the proving ground has been measured and is shown above. This measured data contains a broad spectrum of cycles – from small to large – all of which contribute to the overall fatigue damage.   

The most common method of quantifying cyclic content for fatigue calculations is rainflow cycle counting.  Results are shown below. 

Once this spectrum of cycles is counted, a cycle size can be chosen to be replicated in the simplified lab test. The cycle size should not be larger than the largest cycle observed in the measured loading or else the failure mode may be changed. Additionally, a very small cycle size might require a very lengthy test in order to replicate equivalent fatigue damage. Therefore, a balance must be made to select a cycle size that is large enough for the lab test to complete within a target duration, yet not too large. 

Step 2: Calculating equivalent damage loading

The final step is to compare the failure behavior from the track test and lab test(s). It is possible to perform forensics on the broken faces of a failed part to assess the failure mode. Alternatively, the life data results from each population of failed parts can be model statistically and compared. While several statistical models could be used, Weibull is often selected due to its flexibility. The parameters  and  can describe the failure behavior and time to failure respectively. When using a level of confidence, these parameters can then be described as ranges.

Step 3: Failure mode comparison

Suppose you followed the steps above and create two possible test loading specs: 

Lab test A: A large cycle repeated 50,000 times 

Lab test BA small cycle repeated 200,000 repeats 

Test A has clear benefits in that it will take less time to get results! But maybe you want to know which option is a better durability test.  

You run the product validation test using both newly-created equivalent damage lab loadings, failing 6 samples in each test. Fatigue damage calculations allow the lab failure times to be correlated back to equivalent proving ground laps. Previous testing on the proving ground also returned 6 failures.

The final step is to compare the failure behavior from the proving ground and lab test(s). It is common to perform forensics on the broken faces of broken parts to assess the failure mode – with the assumption that similar failure surfaces implies similar failure modes.

Statistics can also aid this comparison. The life data results from each population of failed parts can be statistically modelled and compared. While several statistical models could be used, the Weibull distribution is often selected due to its flexibility. Weibull parameters β and η can describe the failure behavior and time to failure, respectively. These values can be calculated for each set of failure data and then compared to assess similarities or differences. Further, confidence bounds can be introduced and these parameters can then be described as ranges.

Once each population is modeled, β and η at a specified level of confidence can be compared. Visually, the easiest comparison method is on a contour plot. Separation between contours signifies populations are statistically different at the specified level of confidence.

This plot shows several contours of Weibull parameters: black is lab test A, red is lab test B, and orange is the proving ground. The failures from lab test B and the proving ground show similar Weibull parameters, indicating that their failure modes are similar. Lab test A shows drastically different Weibull characteristics, indicative of a different failure mode entirely. This provides us with statistical evidence that while lab test A has the benefit of a shorter test duration, it’s actually resulted in a different failure mode! 

 

This example was used during a workshop at the 2019 Prenscia User Group Meeting to explore the approach, share best practices, and discover ways to apply this method in daily practice. We have found that this approach works well for creating lab test from proving grounds with equivalent damage. We are confident that if you need to create a lab test specification, this method will allow you to reduce test time and cost while assessing failure mode behavior. 

See all upcoming opportunities to get engaged with HBK tools at an event or training course near you.