In general, there are two primary methods for measuring forces in pressing processes:
This method involves installing a force transducer i directly in the path of the force withing the pressing machine. Typical sensors used include the C6b sensors and, in some cases, the high precision force transducers U10M or U10F. This approach allows for the most accurate force measurements, as these sensors come pre-calibrated, enabling immediate measurements without the need for on-site calibration.
Press forces can be very high, reaching up to the Meganewton range. While HBK offers force sensors capable of handling these high forces, it’s important to note that these models can be quite heavy, sometimes exceeding 100 kg, and their installation requires significant effort.
Typical sensors used include the C6b sensors and, in some cases, the high precision force transducers U10M or U10F
Indirect fore measurements are performed by using strain gauges or so-called strain links, or extensometers, such as the SLH700 series from HBK.
The press force is transferred through machine frame, causing strain on the surface of the force leading [SC1] machine parts. In many cases, this strain is linearly related to the press force. Strain links are installed at suitable locations on the press, converting the strain into a measurable voltage signal. This principle has been known for decades and used in thousands of applications.
If the goal is to measure the force in Newtons or another unit, calibration is required after mounting the strain link. This involves substituting the pressing tool and/or workpiece with a reference sensor. Force is then applied to the setup, and the output signals from both the reference force transducer and the strain link are measured in parallel. This process must be performed for at least one force, though it is common practice to use several load steps and repeat the calibration. By considering the force measurement and the strain link output, the sensitivity of the strain link can be calculated, enabling force measurement in Newtons using an extensometer.
Mounting strain gauges is easy, as the devices are installed with just two M6 screws on the press. It is important to remove any paint and ensure the surface is grease-free. However, since the required force for an SLH strain link is low (just 600 N for a strain of 500 µm/m), the preparation requirements for the measurement point are minimal.
The optimal mounting locations can vary depending on the specific case. See examples in the pictures below.
While strain links may not offer the same precision as force transducers, they come with several advantages:
Strain links are available as passive strain gauge-based sensors, which require an amplifier module to amplify the small output signal and provide a usable signal to the control system.
There are also extensometers with built in amplifiers, eliminating the need for an external amplifier module. Which version is suitable in which situation?
When using a single strain link, models with built-in amplifiers are generally more cost effective and provide a more reliable output signal (current or voltage output instead of mV/V signal).
In many cases, strain links are connected both electrically and mechanically in a parallel mounting configuration. This setup is often used to minimise the influence of bending on the measurement result.
In case of pure tensile or compressive strain, both sensors in the example above measure the same strain in the same direction. If bending occurs, one element measures positive strain while the other element measures negative strain. This results in a zero output, achieving bending moment compensation.
It is also possible to use four sensors from the SLH series and connect them in parallel. However, a parallel setup is much easier with non-amplified extensometers and an external amplifier. The passive SLH are designed for this measurement situation: their high input resistance of 1000 Ohms allows for the connection of four or more sensors in parallel without issues related to low sensor impedance with standard market instruments. Additionally, the sensors are adjusted for the relationship between output resistance and rated output, which is important for parallel setups.
Many available strain transducers with an integrated amplifier module only have a fixed amplification. For example, 500 µm/m corresponds to an output signal of 10 V. The fundamental drawback of this method is that the maximum output signal depends upon the given amplification, which cannot be changed. If, a strain of 200 µm/m is used as the input signal, the resulting output voltage is 4 V. This can lead to unsatisfactory results, if the next element in the measurement chain is a module that has a low resolution or increased noise.
SLH700VA strain links with integrated amplifier electronics overcome this problem by providing the maximum possible output signal at all times, regardless of the intended purpose.
The teach-in procedure is simple:
Additional advantages of this procedure:
SLH sensors offer a cost effective and reliable alternative to load cells for press force measurement with load cells. Here are some key benefits:
This will bring together HBM, Brüel & Kjær, nCode, ReliaSoft, and Discom brands, helping you innovate faster for a cleaner, healthier, and more productive world.
This will bring together HBM, Brüel & Kjær, nCode, ReliaSoft, and Discom brands, helping you innovate faster for a cleaner, healthier, and more productive world.
This will bring together HBM, Brüel & Kjær, nCode, ReliaSoft, and Discom brands, helping you innovate faster for a cleaner, healthier, and more productive world.
This will bring together HBM, Brüel & Kjær, nCode, ReliaSoft, and Discom brands, helping you innovate faster for a cleaner, healthier, and more productive world.
This will bring together HBM, Brüel & Kjær, nCode, ReliaSoft, and Discom brands, helping you innovate faster for a cleaner, healthier, and more productive world.