See All Acoustic End-of-Line Test Systems See All DAQ and instruments See All Electroacoustics See All Software See All Transducers See All Vibration Testing Equipment See All Academy See All Resource Center See All Applications See All Industries See All Insights See All Services See All Support See All Our Business See All Our History See All Our Sustainability Commitment See All Global Presence
arrow_back_ios

Main Menu

See All Actuators See All Combustion Engines See All Durability See All eDrive See All Transmission & Gearboxes See All Turbo Charger See All DAQ Systems See All High Precision and Calibration Systems See All Industrial electronics See All Power Analyser See All S&V Hand-held devices See All S&V Signal conditioner See All Accessories See All DAQ Software See All Drivers & API See All nCode - Durability and Fatigue Analysis See All ReliaSoft - Reliability Analysis and Management See All Test Data Management See All Utility See All Vibration Control See All Acoustic See All Current / voltage See All Displacement See All Load Cells See All Pressure See All Strain Gauges See All Torque See All Vibration See All LDS Shaker Systems See All Power Amplifiers See All Vibration Controllers See All Accessories for Vibration Testing Equipment See All Training Courses See All Whitepapers See All Acoustics See All Asset & Process Monitoring See All Custom Sensors See All Data Acquisition & Analysis See All Durability & Fatigue See All Electric Power Testing See All NVH See All Reliability See All Smart Sensors See All Vibration See All Weighing See All Automotive & Ground Transportation See All Calibration See All Installation, Maintenance & Repair See All Support Brüel & Kjær See All Release Notes See All Compliance See All Our People
arrow_back_ios

Main Menu

See All CANHEAD See All GenHS See All LAN-XI See All MGCplus See All Optical Interrogators See All QuantumX See All SomatXR See All Fusion-LN See All Accessories See All Hand-held Software See All Accessories See All BK Connect / Pulse See All API See All Microphone Sets See All Microphone Cartridges See All Acoustic Calibrators See All Special Microphones See All Microphone Pre-amplifiers See All Sound Sources See All Accessories for acoustic transducers See All Experimental testing See All Transducer Manufacturing (OEM) See All Accessories See All Non-rotating (calibration) See All Rotating See All CCLD (IEPE) accelerometers See All Charge Accelerometers See All Impulse hammers / impedance heads See All Cables See All Accessories See All Electroacoustics See All Noise Source Identification See All Environmental Noise See All Sound Power and Sound Pressure See All Noise Certification See All Industrial Process Control See All Structural Health Monitoring See All Electrical Devices Testing See All Electrical Systems Testing See All Grid Testing See All High-Voltage Testing See All Vibration Testing with Electrodynamic Shakers See All Structural Dynamics See All Machine Analysis and Diagnostics See All Process Weighing See All Calibration Services for Transducers See All Calibration Services for Handheld Instruments See All Calibration Services for Instruments & DAQ See All On-Site Calibration See All Resources See All Software License Management

Table of content

Retail trade customers rely on them and trust them: the measurement results of modern counter scales. Which is hardly surprising, as scales that are used in the trade are subject to legal-for-trade liability and are therefore monitored and checked every two years by officials from the Standards Office. The requirements for these scales are correspondingly high, particularly for the load cells used in them. Their properties with regard to measurement error and repeatability are precisely regulated in the international recommendation OIML R60.

 

So manufacturers of calibration class III scales only install in their products C3 and C6 quality load cells that meet the recommendations of the International Organization of Legal Metrology in Paris. A fact that is usually proved by the OIML certificate accompanying the load cell. But the inspection carried out at regular intervals by the standards officials also confirms that medium accuracy weighing machines produce reliable and precise measurement results, as well as complying with valid verification regulations. At the actual time of verification, the prevailing ambient conditions are relatively constant, particularly the consistent ambient temperature. So the stamping of a medium accuracy weighing machine by the competent Standards Office does not automatically confirm compliance with the recommendations of OIML R60, whose testing is based on far stricter test conditions. This is why, in the course of quality control and quality assurance measures, the latest generation of high-precision HBM, C6-quality load cells were tested under laboratory conditions. The equivalent products of other manufacturers were examined in parallel, under identical conditions. The test setup and ambient conditions matched those of the PTB (German Metrology Institute) in Brunswick. In the test, HBM’s precix series – the new platform load cells range for legal-for-trade scales of accuracy class C6 – returned a series of precise measurement results. Linearity and hysteresis showed ideal values. A fact that became immediately obvious from looking at the stepped curves and test reports for the HBM load cells that were tested. On the other hand, the performance of the C6-quality load cells from competitors that were tested under identical conditions, was more than surprising. Although the accuracy data for the measurements at different temperatures prescribed under OIML fell within the tolerances, there was already a wide spread. For so-called creep, however, the products tested did not meet the prescribed requirements, unlike the HBM precix series.


This result has consequences, as, in fluctuating temperatures, medium accuracy weighing machines with inaccurate load cells show considerable measurement errors, which are paid for by the customer, and/or the user. But the new HBM load cell series precix, for high-precision weighing, has the remedy, even under inconsistent ambient conditions.

Something you can rely on: HBM C6-quality load cells

With precix, HBM provides load cells that, as standard, have an acceptable number of 6000 verification intervalsin the legal-for-trade range. The accuracy of these load cells, which is also called C6-quality (as per international recommendation OIML R60), has direct advantages for you, compared with standard load cells with 3000 verification intervals:
  • Cost saving thanks to greater load cell flexibility: Instead of using several scales for the different weighing ranges and accuracies, you now only need one scale with precix! Where previously, for example, you needed one scale with a 15 kg (approx. 33 lbs) weighing range with 5 g (approx. 0,18 oz) intervals, as well as a scale with 30 kg/10 g (66 lbs/0,35 oz) now you only need one, with a 30 kg/5 g (approx. 66 lbs/ 0,18 oz) weighing range, which even manages without switching intervals.
  • Applications, where the use of legal-for-trade scales is not prescribed, can also achieve far greater weighing accuracy. This applies in particular to weighing when there are changes in temperature.