See All Acoustic End-of-Line Test Systems See All DAQ and instruments See All Electroacoustics See All Software See All Transducers See All Vibration Testing Equipment See All Academy See All Resource Center See All Applications See All Industries See All Insights See All Services See All Support See All Our Business See All Our History See All Our Sustainability Commitment See All Global Presence
arrow_back_ios

Main Menu

See All Actuators See All Combustion Engines See All Durability See All eDrive See All Transmission & Gearboxes See All Turbo Charger See All DAQ Systems See All High Precision and Calibration Systems See All Industrial electronics See All Power Analyser See All S&V Hand-held devices See All S&V Signal conditioner See All Accessories See All DAQ Software See All Drivers & API See All nCode - Durability and Fatigue Analysis See All ReliaSoft - Reliability Analysis and Management See All Test Data Management See All Utility See All Vibration Control See All Acoustic See All Current / voltage See All Displacement See All Load Cells See All Pressure See All Strain Gauges See All Torque See All Vibration See All LDS Shaker Systems See All Power Amplifiers See All Vibration Controllers See All Accessories for Vibration Testing Equipment See All Training Courses See All Whitepapers See All Acoustics See All Asset & Process Monitoring See All Custom Sensors See All Data Acquisition & Analysis See All Durability & Fatigue See All Electric Power Testing See All NVH See All Reliability See All Smart Sensors See All Vibration See All Weighing See All Automotive & Ground Transportation See All Calibration See All Installation, Maintenance & Repair See All Support Brüel & Kjær See All Release Notes See All Compliance See All Our People
arrow_back_ios

Main Menu

See All CANHEAD See All GenHS See All LAN-XI See All MGCplus See All Optical Interrogators See All QuantumX See All SomatXR See All Fusion-LN See All Accessories See All Hand-held Software See All Accessories See All BK Connect / Pulse See All API See All Microphone Sets See All Microphone Cartridges See All Acoustic Calibrators See All Special Microphones See All Microphone Pre-amplifiers See All Sound Sources See All Accessories for acoustic transducers See All Experimental testing See All Transducer Manufacturing (OEM) See All Accessories See All Non-rotating (calibration) See All Rotating See All CCLD (IEPE) accelerometers See All Charge Accelerometers See All Impulse hammers / impedance heads See All Cables See All Accessories See All Electroacoustics See All Noise Source Identification See All Environmental Noise See All Sound Power and Sound Pressure See All Noise Certification See All Industrial Process Control See All Structural Health Monitoring See All Electrical Devices Testing See All Electrical Systems Testing See All Grid Testing See All High-Voltage Testing See All Vibration Testing with Electrodynamic Shakers See All Structural Dynamics See All Machine Analysis and Diagnostics See All Process Weighing See All Calibration Services for Transducers See All Calibration Services for Handheld Instruments See All Calibration Services for Instruments & DAQ See All On-Site Calibration See All Resources See All Software License Management

Type 9699

Our primary level microphone calibration system for calibration of laboratory standard microphones.

img

Type 9699

expand_more
chevron_left
chevron_right

A primary level microphone calibration system for calibration of laboratory standard microphones.

Type 9699 applies the pressure reciprocity calibration technique and calibrates to the highest possible accuracy. A free-field system is available as Type 9799. The system performs pressure reciprocity calibration according to the method described in IEC 61094-2 for determining the pressure sensitivity of microphones described in IEC 61094-1 (Laboratory Standard Microphones).

The system is intended for National Metrology Institutes and other high-level laboratories. It is a turnkey system for routine measurements, which can be set up to meet the requirements of the user.

USE SCENARIOS

  • Primary open-circuit pressure sensitivity calibration of laboratory standard microphones
  • Measurements according to IEC 61094-2 on IEC 61094-1 microphone types:
    • LS1P (for example, Type 4160)
    • LS2aP (for example, Type 4180)
  • Measurement of static pressure coefficient using integral pressure chamber

CALIBRATION SYSTEM FEATURES

  • Fast PC-controlled determination of electrical transfer impedance
  • Measurement and calibration data stored on disk or printed as hard copy
  • Frequency range: 20Hz to 10kHz (LS1), 20Hz to 20kHz (LS2)
  • Unique vibration and ambient noise damped microphone mounting stand
  • Dimensionally stable plane-wave sapphire couplers

The system can work in a ‘normal’ laboratory environment with no specific precautions with respect to background noise and vibration.

File

Description

Type

Languages

Size

Reciprocity Calibration System Type 9699-A, Reciprocity Calibration Apparatus Type 5998-A

Technical Document English 730 KB