See All Acoustic End-of-Line Test Systems See All DAQ and instruments See All Electroacoustics See All Software See All Transducers See All Vibration Testing Equipment See All Academy See All Resource Center See All Applications See All Industries See All Insights See All Services See All Support See All Our Business See All Our History See All Our Sustainability Commitment See All Global Presence
arrow_back_ios

Main Menu

See All Actuators See All Combustion Engines See All Durability See All eDrive See All Production Testing Sensors See All Transmission & Gearboxes See All Turbo Charger See All DAQ Systems See All High Precision and Calibration Systems See All Industrial electronics See All Power Analyser See All S&V Hand-held devices See All S&V Signal conditioner See All Test Solutions See All DAQ Software See All Drivers & API See All nCode - Durability and Fatigue Analysis See All ReliaSoft - Reliability Analysis and Management See All Test Data Management See All Utility See All Vibration Control See All Acoustic See All Current / voltage See All Displacement See All Load Cells See All Pressure See All Strain Gauges See All Torque See All Vibration See All LDS Shaker Systems See All Power Amplifiers See All Vibration Controllers See All Accessories for Vibration Testing Equipment See All Training Courses See All Whitepapers See All Acoustics See All Asset & Process Monitoring See All Custom Sensors See All Data Acquisition & Analysis See All Durability & Fatigue See All Electric Power Testing See All NVH See All Reliability See All Smart Sensors See All Vibration See All Weighing See All Automotive & Ground Transportation See All Calibration See All Installation, Maintenance & Repair See All Support Brüel & Kjær See All Release Notes See All Compliance See All Our People
arrow_back_ios

Main Menu

See All CANHEAD See All GenHS See All LAN-XI See All MGCplus See All Optical Interrogators See All QuantumX See All SomatXR See All Accessories See All Accessories See All BK Connect / Pulse See All API See All Microphone Sets See All Microphone Cartridges See All Acoustic Calibrators See All Special Microphones See All Microphone Pre-amplifiers See All Sound Sources See All Accessories for acoustic transducers See All Experimental testing See All Transducer Manufacturing (OEM) See All Accessories See All Non-rotating (calibration) See All Rotating See All CCLD (IEPE) accelerometers See All Charge Accelerometers See All Impulse hammers / impedance heads See All Cables See All Accessories See All Electroacoustics See All Noise Source Identification See All Environmental Noise See All Sound Power and Sound Pressure See All Noise Certification See All Industrial Process Control See All Structural Health Monitoring See All Electrical Devices Testing See All Electrical Systems Testing See All Grid Testing See All High-Voltage Testing See All Vibration Testing with Electrodynamic Shakers See All Structural Dynamics See All Machine Analysis and Diagnostics See All Calibration Services for Transducers See All Calibration Services for Handheld Instruments See All Calibration Services for Instruments & DAQ See All On-Site Calibration See All Resources See All Software License Management

MVD

MVD series amplifiers have a wide range of functions that make them ideally suited to be used in many different applications.

img

MVD

expand_more
chevron_left
chevron_right

MVD Series Measuring Amplifiers: Carrier Frequency and Direct Current Amplifiers

The MVD2555 and MVD2510 measuring amplifiers are ideally suited to be used in industrial measurements. Their robust, dust-protected housing has been optimized for panel mounting. The amplifiers feature Min/Max memories, limit value switches, and different signal types to ensure maximum reliability in their applications. Both devices come with a freely scalable analog output that allows fast adaptation to individual measurement conditions and guarantees high-quality results.

  • Accuracy class: 0.1
  • Housing dimensions: 153 x 72 x 212 mm (W x H x D)
  • Degree of protection: IP51 (front)

High-Quality Results

  • Accurate measurement due to 0.1 accuracy class
  • Clear results due to the presence of a digital filter that can be adjusted in multiple steps 
  • High signal quality thanks to a low-drift design
  • High electromagnetic compatibility

Accurate measurement results due to a digital filter, a low-drift design, and high electromagnetic compatibility

Universal Application

  • Easy configuration based on an integrated parameter memory (formulations)
  • Freely scalable analog output (±10 V, ±20 mA, 4-20 mA)
  • Integrated peak-value memory
  • Multilingual, password-protected setup menu for device parameterization

Wide field of applications due to parameter memory and four limit value switches

Safe Use

  • Portable housing with carrying handle that also serves as a stand
  • Easy-to-read, 10-digit, red LED display
  • Intuitive control through robust membrane keypad with seven button elements
  • Integrated diagnostics, error, and alarm signals

Reliable use in industrial applications due to alarm signals and an easy-to-read LED display

File

Description

Type

Languages

Size

MVD2555-RS485 - Data Sheet (B00720)

MVD2555-RS485 - Data Sheet

Technical Document English 256 KB
MVD2555 - Operating Manual (A05957)

MVD2555 - Operating Manual

Technical Document English, German 1 MB
MVD2555 - EU Declaration of Conformity (ce046)

MVD2555 - EU Declaration of Conformity

Certificate English 623 KB
MVD
Number of inputs Single channel
Input Strain gauge full/half bridge, Inductive bridge, Resistance
Interface Analogue, Digital I/O, RS-232
Accuracy class 0.1
Sample rate [S/s] 50 S/s
Housing Field mounted
Internal logic Calculated channel
Legal for trade No