arrow_back_ios

Main Menu

See All Acoustic End-of-Line Test Systems See All DAQ and instruments See All Electroacoustics See All Software See All Transducers See All Vibration Testing Equipment See All Academy See All Resource Center See All Applications See All Industries See All Insights See All Services See All Support See All Our Business See All Our History See All Our Sustainability Commitment See All Global Presence
arrow_back_ios

Main Menu

See All Actuators See All Combustion Engines See All Durability See All eDrive See All Transmission & Gearboxes See All Turbo Charger See All DAQ Systems See All High Precision and Calibration Systems See All Industrial electronics See All Power Analyser See All S&V Hand-held devices See All S&V Signal conditioner See All Accessories See All DAQ Software See All Drivers & API See All nCode - Durability and Fatigue Analysis See All ReliaSoft - Reliability Analysis and Management See All Test Data Management See All Utility See All Vibration Control See All Acoustic See All Current / voltage See All Displacement See All Load Cells See All Pressure See All Strain Gauges See All Torque See All Vibration See All LDS Shaker Systems See All Power Amplifiers See All Vibration Controllers See All Accessories for Vibration Testing Equipment See All Training Courses See All Whitepapers See All Acoustics See All Asset & Process Monitoring See All Custom Sensors See All Data Acquisition & Analysis See All Durability & Fatigue See All Electric Power Testing See All NVH See All Reliability See All Smart Sensors See All Vibration See All Weighing See All Automotive & Ground Transportation See All Calibration See All Installation, Maintenance & Repair See All Support Brüel & Kjær See All Release Notes See All Compliance See All Our People
arrow_back_ios

Main Menu

See All CANHEAD See All GenHS See All LAN-XI See All MGCplus See All Optical Interrogators See All QuantumX See All SomatXR See All Fusion-LN See All Accessories See All Hand-held Software See All Accessories See All BK Connect / Pulse See All API See All Microphone Sets See All Microphone Cartridges See All Acoustic Calibrators See All Special Microphones See All Microphone Pre-amplifiers See All Sound Sources See All Accessories for acoustic transducers See All Experimental testing See All Transducer Manufacturing (OEM) See All Accessories See All Non-rotating (calibration) See All Rotating See All CCLD (IEPE) accelerometers See All Charge Accelerometers See All Impulse hammers / impedance heads See All Cables See All Accessories See All Electroacoustics See All Noise Source Identification See All Environmental Noise See All Sound Power and Sound Pressure See All Noise Certification See All Industrial Process Control See All Structural Health Monitoring See All Electrical Devices Testing See All Electrical Systems Testing See All Grid Testing See All High-Voltage Testing See All Vibration Testing with Electrodynamic Shakers See All Structural Dynamics See All Machine Analysis and Diagnostics See All Process Weighing See All Calibration Services for Transducers See All Calibration Services for Handheld Instruments See All Calibration Services for Instruments & DAQ See All On-Site Calibration See All Resources See All Software License Management

1-AED9401A

Basic device (RS485/CAN/DN) for AD103C

Housing for AD103C
with interfaces: CAN Bus or Device Net
in- and out controlling signals
operating voltage range 18 up to 30 V

img

Basic device (RS485/CAN/DN) for AD103C

expand_more
chevron_left
chevron_right

AED Digital Transducer Electronics: Turn Analog Load Cells into Digital All-rounders

The AED transducer electronics digitizes the signals from analogue load cells, thus ensuring digital precision in new or existing systems. The installation and commissioning are done quickly and easily due to the bus interfaces and integrated PC software.

  • AED measurement chain: Comprising of an AD103C measuring amplifier board, a basic device, and PanelX software
  • Accuracy class: 0.01 with a test report for 10000 d, class III according to OIML R76
  • Interfaces: RS-232, RS-485, CANopen, DeviceNet, and Profibus DP V1
  • Measurement inputs: Two control inputs and four limit outputs

High measurement quality

  • AD103C: DC amplifier board for static and dynamic applications 
  • High sample rate (1200Hz) and resolution 
  • RS-232 diagnostic interface

Reliable and stable readings over many years.

Certified

  • Test report for 10000 d, class III according to OIML R76 
  • Storage of user settings
  • Command set for complete filling and dosing functions
  • Use in non-automatic scales (NAWI) and automatic scales (AWI)

OIML R76-certified as a component for all kinds of legal-for-trade scales.

Robust

  • The implementation effort is low due to the bus interfaces of the matching AED basic devices 
  • IP65 degree of protection
  • The device is started up via a PC and the free PanelX software

Universal application and high investment security.

File

Description

Type

Languages

Size

AED - Quick Start Guide (A01780)

AED9201B - Quick Start Guide

Technical Document English, German 2 MB
AED9401A - Data sheet (B01770)

AED9401A - Data sheet

Technical Document English 144 KB
AED - User Manual (A05803)

AED - User Manual

Technical Document English, German 3 MB
AED9401A - EU Declaration of Conformity (ce243)

AED9401A - EU Declaration of Conformity

Certificate English 605 KB
AED9401A, AED9301B & AED9201B - CAD

AED9401A, AED9301B & AED9201B - CAD

CAD File English, Italian, French, Portuguese, Chinese, Korean, German, Spanish, Japanese 1 MB
Key Attributes: Industrial Electronics
Number of inputs Single channel
Input Strain gauge full/half bridge
Interface RS-485, CAN, DeviceNet, Digital I/O
Accuracy class 0.01
Sample rate [S/s] 1200 S/s
Housing Field mounted
Internal logic None
Legal for trade Yes