See All Acoustic End-of-Line Test Systems See All DAQ and instruments See All Electroacoustics See All Software See All Transducers See All Vibration Testing Equipment See All Academy See All Resource Center See All Applications See All Industries See All Insights See All Services See All Support See All Our Business See All Our History See All Our Sustainability Commitment See All Global Presence
arrow_back_ios

Main Menu

See All Actuators See All Combustion Engines See All Durability See All eDrive See All Transmission & Gearboxes See All Turbo Charger See All DAQ Systems See All High Precision and Calibration Systems See All Industrial electronics See All Power Analyser See All S&V Hand-held devices See All S&V Signal conditioner See All Accessories See All DAQ Software See All Drivers & API See All nCode - Durability and Fatigue Analysis See All ReliaSoft - Reliability Analysis and Management See All Test Data Management See All Utility See All Vibration Control See All Acoustic See All Current / voltage See All Displacement See All Load Cells See All Pressure See All Strain Gauges See All Torque See All Vibration See All LDS Shaker Systems See All Power Amplifiers See All Vibration Controllers See All Accessories for Vibration Testing Equipment See All Training Courses See All Whitepapers See All Acoustics See All Asset & Process Monitoring See All Custom Sensors See All Data Acquisition & Analysis See All Durability & Fatigue See All Electric Power Testing See All NVH See All Reliability See All Smart Sensors See All Vibration See All Weighing See All Automotive & Ground Transportation See All Calibration See All Installation, Maintenance & Repair See All Support Brüel & Kjær See All Release Notes See All Compliance See All Our People
arrow_back_ios

Main Menu

See All CANHEAD See All GenHS See All LAN-XI See All MGCplus See All Optical Interrogators See All QuantumX See All SomatXR See All Fusion-LN See All Accessories See All Hand-held Software See All Accessories See All BK Connect / Pulse See All API See All Microphone Sets See All Microphone Cartridges See All Acoustic Calibrators See All Special Microphones See All Microphone Pre-amplifiers See All Sound Sources See All Accessories for acoustic transducers See All Experimental testing See All Transducer Manufacturing (OEM) See All Accessories See All Non-rotating (calibration) See All Rotating See All CCLD (IEPE) accelerometers See All Charge Accelerometers See All Impulse hammers / impedance heads See All Cables See All Accessories See All Electroacoustics See All Noise Source Identification See All Environmental Noise See All Sound Power and Sound Pressure See All Noise Certification See All Industrial Process Control See All Structural Health Monitoring See All Electrical Devices Testing See All Electrical Systems Testing See All Grid Testing See All High-Voltage Testing See All Vibration Testing with Electrodynamic Shakers See All Structural Dynamics See All Machine Analysis and Diagnostics See All Process Weighing See All Calibration Services for Transducers See All Calibration Services for Handheld Instruments See All Calibration Services for Instruments & DAQ See All On-Site Calibration See All Resources See All Software License Management

W1ELA/0

The W1ELA/0 displacement transducer in plunger version enables precise measurement of short displacements directly during the process.

img

W1ELA/0

expand_more
chevron_left
chevron_right

W1ELA/0 Displacement Transducer: Inductive Displacement Measurement in Machines and Systems; Nominal (Rated) Measuring Range +/– 1 Mm

The extremely compact W1ELA/0 displacement transducer consists almost entirely of just the coil body and plunger. This allows the sensor to be perfectly placed in the relevant machine, system, or test bench. This is further supported by the widely approved temperature range of the sensor from –55° C to +130° C. The W1ELA/0 displacement transducer can be used for reliable acquisition of the nominal (rated) displacement, moving outward from the center position in both directions.

The coil body contains two measuring coils arranged one behind the other, which together form an inductive half bridge. This must be completed in a 4.8 kHz carrier frequency amplifier to form a full bridge circuit.

Minimal design

  • Only two basic components: Coil body and plunger
  • Open design: No unnecessary enclosure
  • Half bridge circuit in the transducer; completion to form a full bridge in the amplifier
  • Dimensions of the coil body: Diameter 12 mm x length 20 mm

Space-saving and designed for direct integration

Wide range of uses

  • Large temperature range from –55°C to +130 °C
  • High shock resistance: Coil body up to 500 m/s2, plunger up to 1000 m/s2
  • Low weight: Coil body 11 g, plunger 3 g

Versatile range of applications in machines, systems and test benches

Application-oriented

  • Easy to mount by clamping the coil body
  • Fine thread on plunger ensures exact zero point setting
  • Wear-free measurement principle
  • Continuous plunger channel prevents damage due to excess stroke

Practical construction: Easy, rugged, reliable. 

File

Description

Type

Languages

Size

W1ELA/0 - Data Sheet (B02620)

W1ELA/0 - Data Sheet

Technical Document English 43 KB
W1ELA/0 - Mounting instructions (A02621)

W1ELA - Mounting Instructions

Technical Document English, German 118 KB
W1E - EU Declaration of Conformity (ce005)

W1E - EU Declaration of Conformity

Certificate English 614 KB
W1ELA/0
Type/technology Inductive
Application Short length
Measurement range [mm] 1 mm
Measurement range [in] 0.039 in
Measurement range (base unit) 1 mm
Degree of protection IP20
Output signal Passive
Mechanical connection Loose plunger
Linearity deviation 0.2 %
Shaft diameter [mm] 12 mm
Shaft diameter [in] 0.472 in
Length [mm] 70.5 mm
Length [in] 2.78 in