See All Acoustic End-of-Line Test Systems See All DAQ and instruments See All Electroacoustics See All Software See All Transducers See All Vibration Testing Equipment See All Academy See All Resource Center See All Applications See All Industries See All Insights See All Services See All Support See All Our Business See All Our History See All Our Sustainability Commitment See All Global Presence
arrow_back_ios

Main Menu

See All Actuators See All Combustion Engines See All Durability See All eDrive See All Production Testing Sensors See All Transmission & Gearboxes See All Turbo Charger See All DAQ Systems See All High Precision and Calibration Systems See All Industrial electronics See All Power Analyser See All S&V Hand-held devices See All S&V Signal conditioner See All Test Solutions See All DAQ Software See All Drivers & API See All nCode - Durability and Fatigue Analysis See All ReliaSoft - Reliability Analysis and Management See All Test Data Management See All Utility See All Vibration Control See All Acoustic See All Current / voltage See All Displacement See All Load Cells See All Pressure See All Strain Gauges See All Torque See All Vibration See All LDS Shaker Systems See All Power Amplifiers See All Vibration Controllers See All Accessories for Vibration Testing Equipment See All Training Courses See All Whitepapers See All Acoustics See All Asset & Process Monitoring See All Custom Sensors See All Data Acquisition & Analysis See All Durability & Fatigue See All Electric Power Testing See All NVH See All Reliability See All Smart Sensors See All Vibration See All Weighing See All Automotive & Ground Transportation See All Calibration See All Installation, Maintenance & Repair See All Support Brüel & Kjær See All Release Notes See All Compliance See All Our People
arrow_back_ios

Main Menu

See All CANHEAD See All GenHS See All LAN-XI See All MGCplus See All Optical Interrogators See All QuantumX See All SomatXR See All Accessories See All Accessories See All BK Connect / Pulse See All API See All Microphone Sets See All Microphone Cartridges See All Acoustic Calibrators See All Special Microphones See All Microphone Pre-amplifiers See All Sound Sources See All Accessories for acoustic transducers See All Experimental testing See All Transducer Manufacturing (OEM) See All Accessories See All Non-rotating (calibration) See All Rotating See All CCLD (IEPE) accelerometers See All Charge Accelerometers See All Impulse hammers / impedance heads See All Cables See All Accessories See All Electroacoustics See All Noise Source Identification See All Environmental Noise See All Sound Power and Sound Pressure See All Noise Certification See All Industrial Process Control See All Structural Health Monitoring See All Electrical Devices Testing See All Electrical Systems Testing See All Grid Testing See All High-Voltage Testing See All Vibration Testing with Electrodynamic Shakers See All Structural Dynamics See All Machine Analysis and Diagnostics See All Calibration Services for Transducers See All Calibration Services for Handheld Instruments See All Calibration Services for Instruments & DAQ See All On-Site Calibration See All Resources See All Software License Management

U15

The cost-effective U15 reference force transducer can be used as a transfer standard and as a master sensor. Measuring range: 10 to 100 % of its capacity.

img

U15

expand_more
chevron_left
chevron_right

U15 Precision Load Cell: Calibrating Forces from 2.5 kN to 2.5 MN

The U15 precision load cell (reference force transducer) reliably measures tensile and compressive force up to 2.5 MN. It is ideally suited for use as the master sensor in calibration machines, for challenging tasks in test benches, and as a transfer standard (e.g. when verifying or calibrating material testing machines or taking transfer measurements to ensure traceability of calibration machines to a standard).

As the transducer is showing vey low displacement, the geometry of the test stand is also stable under load. The U15 precision load cell's high resolution, excellent signal-to-noise ratio and low measurement uncertainty are based on the transducer’s high output signal (>4 mV/V from 25 kN). This allows for optimal utilization of the subsequent electronics’ measuring range. 

U15 meets the requirements of class 0.5 in accordance with ISO 376. Its radially symmetrical design makes the sensor insensitive to temperature gradients. The U15 precision load cell is very robust due to its high IP67 degree of protection and the use of stainless steel materials.

  • Accuracy class (per ISO 376:2011): 0.5 in the range of 10% and 100% of the nominal load 
  • HBM accuracy class: 0.02 to 0.05
  • Capacities: 2.5 kN to 2.5 MN

High accuracy class

  • Complies with the requirements of accuracy class 0.5 per ISO 376 in the range between 10% and 100% of its capacity
  • High output signal, > 4 mV/V for many capacities
  • Signal adjustment to 3 mV/V available as an option
  • Excellent signal-to-noise ratio
  • Good repeatability in varying mounting positions through electronic bending moment compensation
  • Transfer standard for tensile and compressive force up to 1 MN

Standard-compliant precision, also under unfavorable conditions of use. Absolute reliability.

Individual configuration

  • Double bridge version available on request: One output can be used as a reference signal, one output as an input for the machine control (also for machines with high forces and loads). 
  • Application-oriented accessories such as TEDS, ISO 376-compliant load application and knuckle eyes
  • HBM enables the U15 together with the amplifier to be calibrated as a measurement chain (competence of the HBM calibration laboratory)
  • Option: Delivery as a calibrated product (calibration through HBM’s ISO 17025-accredited calibration laboratory) 

Optimal complete solution including calibrated accessories for reliable transfer measurement

Small displacement

  • Small displacement
  • As a result: High stiffness and excellent dynamic behavior
  • High resonance frequency for dynamic calibration tasks
  • Robust due to IP67 degree of protection and hermetic sealing resulting in outstanding long-term stability
  • Small TKZero and low sensitivity to temperature gradients

Measurement accuracy, even in dynamic or harsh conditions. Minimal displacements. 

File

Description

Type

Languages

Size

U15 - Data Sheet (B02231)

U15 - Data Sheet

Technical Document English 463 KB
U15 - Mounting instructions (A02100)

U15 - Mounting Instructions

Technical Document English, Italian, French, Chinese, German 1 MB
K-CAB-F (cable) - Data Sheet (B05374)

K-CAB-F (cable) - Data Sheet

Technical Document English 197 KB
U10M, U10S, U15, C10, C15 - EU Declaration of Conformity (ce313)

U10M, U10S, U15, C10, C15 - EU Declaration of Conformity

Certificate English 918 KB
U15
Capacity group 1-50 kN, 50-500 kN, >500 KN
Capacity (nominal load) [N] 2.5 kN, 5 kN, 10 kN, 25 kN, 50 kN, 100 kN, 250 kN, 500 kN, 1 MN, 2.5 MN
Capacity (nominal load) [lbf] 562 lbf, 1.12 klbf, 2.25 klbf, 5.62 klbf, 11.2 klbf, 22.5 klbf, 56.2 klbf, 112 klbf, 225 klbf, 562 klbf
Capacity in N (nominal load) 2500 N, 5000 N, 10000 N, 25000 N, 50000 N, 100000 N, 250000 N, 500000 N, 1000000 N, 2500000 N
Direction Compression, Tension, Both directions
Strain gauge / piezo Strain Gauge
Calibration Calibrated
Output signal mV/V (passive strain gauge)
HBK Accuracy class 0.5 (ISO376)
Degree of protection IP67
Mechanical adaptation Central thread
Height (without accessories) 114.5 mm, 174.5 mm, 217.3 mm, 307.3 mm, 465.3 mm
Height (without accessories) 4.51 in, 6.87 in, 8.56 in, 12.1 in, 18.32 in
Diameter (without cable or plug) 104.8 mm, 153.9 mm, 203.2 mm, 279 mm, 390 mm
Diameter (without cable or plug) 8.27 in, 10.59 in, 14.49 in, 15.35 in