arrow_back_ios

Main Menu

See All Acoustic End-of-Line Test Systems See All DAQ and instruments See All Electroacoustics See All Software See All Transducers See All Vibration Testing Equipment See All Academy See All Resource Center See All Applications See All Industries See All Insights See All Services See All Support See All Our Business See All Our History See All Our Sustainability Commitment See All Global Presence
arrow_back_ios

Main Menu

See All Actuators See All Combustion Engines See All Durability See All eDrive See All Transmission & Gearboxes See All Turbo Charger See All DAQ Systems See All High Precision and Calibration Systems See All Industrial electronics See All Power Analyser See All S&V Hand-held devices See All S&V Signal conditioner See All Accessories See All DAQ Software See All Drivers & API See All nCode - Durability and Fatigue Analysis See All ReliaSoft - Reliability Analysis and Management See All Test Data Management See All Utility See All Vibration Control See All Acoustic See All Current / voltage See All Displacement See All Load Cells See All Pressure See All Strain Gauges See All Torque See All Vibration See All LDS Shaker Systems See All Power Amplifiers See All Vibration Controllers See All Accessories for Vibration Testing Equipment See All Training Courses See All Whitepapers See All Acoustics See All Asset & Process Monitoring See All Custom Sensors See All Data Acquisition & Analysis See All Durability & Fatigue See All Electric Power Testing See All NVH See All Reliability See All Smart Sensors See All Vibration See All Weighing See All Automotive & Ground Transportation See All Calibration See All Installation, Maintenance & Repair See All Support Brüel & Kjær See All Release Notes See All Compliance See All Our People
arrow_back_ios

Main Menu

See All CANHEAD See All GenHS See All LAN-XI See All MGCplus See All Optical Interrogators See All QuantumX See All SomatXR See All Fusion-LN See All Accessories See All Hand-held Software See All Accessories See All BK Connect / Pulse See All API See All Microphone Sets See All Microphone Cartridges See All Acoustic Calibrators See All Special Microphones See All Microphone Pre-amplifiers See All Sound Sources See All Accessories for acoustic transducers See All Experimental testing See All Transducer Manufacturing (OEM) See All Accessories See All Non-rotating (calibration) See All Rotating See All CCLD (IEPE) accelerometers See All Charge Accelerometers See All Impulse hammers / impedance heads See All Cables See All Accessories See All Electroacoustics See All Noise Source Identification See All Environmental Noise See All Sound Power and Sound Pressure See All Noise Certification See All Industrial Process Control See All Structural Health Monitoring See All Electrical Devices Testing See All Electrical Systems Testing See All Grid Testing See All High-Voltage Testing See All Vibration Testing with Electrodynamic Shakers See All Structural Dynamics See All Machine Analysis and Diagnostics See All Process Weighing See All Calibration Services for Transducers See All Calibration Services for Handheld Instruments See All Calibration Services for Instruments & DAQ See All On-Site Calibration See All Resources See All Software License Management

K-U9C

Configurable force transducer K-U9C

Miniature force transducer U9C for tensile and compressive forces
Accuracy class 0.2
Strain gage measurement system
Nominal (rated) sensitivity 1 mV/V
Stainless steel

img

Configurable force transducer K-U9C

expand_more
chevron_left
chevron_right

The K-U9C is our miniature sensor for tensile and compressive forces - ready to be configured in accordance with your needs.

Find bellow some explanations to our options.

Capacity

The sensor is available in measurement ranges from 50 N to 50 kN.

Cable length

The standard version of the U9C is supplied with a 1.5 m cable (01M5). Additionally, the force transducer is available with the following cable lengths: 3 m (03M0), 5 m (05M0), 6 m (06M0), 7 m (07M0) and 12 m (12M0).

NOTE: Versions with inline amplifiers (VA1, VA2 and VAIO) can only be combined with 1.5 m and 3 m cable lengths.

Electrical connection

If requested, we can mount one of the following connectors on the U9C:

  • Y = Free ends, no plug assembly
  • F = D-sub-HD15, for connecting to MGC+ (e.g. AP01) or Scout amplifiers
  • Q = HD-sub-HD15, for connecting to many HBK signal conditioners in the Quantum series (MX410, Mx440, MX840, MX430, MX238)
  • N = MS plug, for connecting to HBK signal conditioner, such as MGC+ (AP03), DMP or DK38
  • VA1 = With inline amplifier 0 … 10 V
  • VA2 = With inline amplifier 4 … 20 mA
  • VAIO = With inline amplifier IO-Link

Transducer identification

You can order your sensor with a “Transducer Electronic Data Sheet”, TEDS (T). In this case, your sensor is equipped with an electronic memory that is programmed with the technical characteristics of the sensor. If the sensor is connected to an instrument with TEDS 0-wire functionality, for example, HBK's Quantum models or the ClipX modules, the instrument will read out the specific data and the setup process will run automatically.

NOTE: TEDS can only be ordered in conjunction with a plug option (Option F, Q or N). TEDS is only available for sensors without an inline amplifier module.

Firmware version

If you order a U9C with the VAIO option, you will get the latest firmware version, unless you choose an older version that is still available.

File

Description

Type

Languages

Size

U9C - Mounting instructions (A03815)

U9C - Mounting Instructions

Technical Document English, Italian, French, German 1 MB
U9C - Data Sheet (B03812)

U9C - Data Sheet

Technical Document English 181 KB
U9C - Quick Start Guide (A06135)

U9C - Quick Start Guide

Technical Document English, Italian, French, Chinese, German 441 KB
Reliable force measurement - Brochure (S00859)

Reliable force measurement - Brochure

Marketing Document English 1 MB
U9C capacity 100 N - CAD

U9C capacity 100 N - CAD

CAD File English, Italian, French, Portuguese, Chinese, Korean, German, Spanish, Japanese 365 KB
U9C Knuckle Eye capacity 50N-1kN - CAD

U9C Knuckle Eye capacity 50N-1kN - CAD

CAD File English, Italian, French, Portuguese, Chinese, Korean, German, Spanish, Japanese 373 KB
U9C/U93a Inline Amplifier AV12 : - CAD

U9C/U93a Inline Amplifier AV12 : - CAD

CAD File English, Italian, French, Portuguese, Chinese, Korean, German, Spanish, Japanese 2 MB
U9C capacity 1 kN - CAD

U9C capacity 1 kN - CAD

CAD File English, Italian, French, Portuguese, Chinese, Korean, German, Spanish, Japanese 318 KB
U9C capacity 20 kN - CAD

U9C capacity 20 kN - CAD

CAD File English, Italian, French, Portuguese, Chinese, Korean, German, Spanish, Japanese 351 KB
U9C Knuckle Eye capacity 2kN-20kN - CAD

U9C Knuckle Eye capacity 2kN-20kN - CAD

CAD File English, Italian, French, Portuguese, Chinese, Korean, German, Spanish, Japanese 378 KB
U9C capacity 50 kN - CAD

U9C capacity 50 kN - CAD

CAD File English, Italian, French, Portuguese, Chinese, Korean, German, Spanish, Japanese 332 KB
U9C Knuckle Eye capacity 50kN - CAD

U9C Knuckle Eye capacity 50kN - CAD

CAD File English, Italian, French, Portuguese, Chinese, Korean, German, Spanish, Japanese 362 KB
U9C capacity 10 kN - CAD

U9C capacity 10 kN - CAD

CAD File English, Italian, French, Portuguese, Chinese, Korean, German, Spanish, Japanese 341 KB
U9C capacity 5 kN - CAD

U9C capacity 5 kN - CAD

CAD File English, Italian, French, Portuguese, Chinese, Korean, German, Spanish, Japanese 341 KB
U9C capacity 0.5 kN - CAD

U9C capacity 0.5 kN - CAD

CAD File English, Italian, French, Portuguese, Chinese, Korean, German, Spanish, Japanese 313 KB
U9C capacity 200 N - CAD

U9C capacity 200 N - CAD

CAD File English, Italian, French, Portuguese, Chinese, Korean, German, Spanish, Japanese 365 KB
U9C capacity 2 kN - CAD

U9C capacity 2 kN - CAD

CAD File English, Italian, French, Portuguese, Chinese, Korean, German, Spanish, Japanese 341 KB
U9C capacity 50 N - CAD

U9C capacity 50 N - CAD

CAD File English, Italian, French, Portuguese, Chinese, Korean, German, Spanish, Japanese 365 KB
Key attributes for industrial force transducers
Capacity group < 1 kN, 1-50 kN
Capacity (nominal load) [N] 50 N, 100 N, 200 N, 0.5 kN, 1 kN, 2 kN, 5 kN, 10 kN, 20 kN, 50 kN
Capacity (nominal load) [lbf] 11.2 lbf, 22.5 lbf, 45 lbf, 112 lbf, 225 lbf, 450 lbf, 1.12 klbf, 2.5 klbf, 4.5 klbf, 11.2 klbf
Direction Both directions
Strain gauge / piezo Strain Gauge
Calibration Calibrated
Output signal mV/V (passive strain gauge), Voltage (0…10V), Current (4-20mA), IO-Link
HBK Accuracy class 0.2
Load cell design Miniature sensor
Degree of protection IP67
Mechanical adaptation Central thread
Height (without accessories) 42 mm, 44.5 mm, 60 mm, 84 mm
Height (without accessories) 1.65 in, 1.75 in, 2.36 in, 3.31 in
Diameter (without cable or plug) 26 mm, 46 mm, 18 mm
Diameter (without cable or plug) 1.02362 in, 1.81102 in