See All Acoustic End-of-Line Test Systems See All DAQ and instruments See All Electroacoustics See All Software See All Transducers See All Vibration Testing Equipment See All Academy See All Resource Center See All Applications See All Industries See All Insights See All Services See All Support See All Our Business See All Our History See All Our Sustainability Commitment See All Global Presence
arrow_back_ios

Main Menu

See All Actuators See All Combustion Engines See All Durability See All eDrive See All Transmission & Gearboxes See All Turbo Charger See All DAQ Systems See All High Precision and Calibration Systems See All Industrial electronics See All Power Analyser See All S&V Hand-held devices See All S&V Signal conditioner See All Accessories See All DAQ Software See All Drivers & API See All nCode - Durability and Fatigue Analysis See All ReliaSoft - Reliability Analysis and Management See All Test Data Management See All Utility See All Vibration Control See All Acoustic See All Current / voltage See All Displacement See All Load Cells See All Pressure See All Strain Gauges See All Torque See All Vibration See All LDS Shaker Systems See All Power Amplifiers See All Vibration Controllers See All Accessories for Vibration Testing Equipment See All Training Courses See All Whitepapers See All Acoustics See All Asset & Process Monitoring See All Custom Sensors See All Data Acquisition & Analysis See All Durability & Fatigue See All Electric Power Testing See All NVH See All Reliability See All Smart Sensors See All Vibration See All Weighing See All Automotive & Ground Transportation See All Calibration See All Installation, Maintenance & Repair See All Support Brüel & Kjær See All Release Notes See All Compliance See All Our People
arrow_back_ios

Main Menu

See All CANHEAD See All GenHS See All LAN-XI See All MGCplus See All Optical Interrogators See All QuantumX See All SomatXR See All Fusion-LN See All Accessories See All Hand-held Software See All Accessories See All BK Connect / Pulse See All API See All Microphone Sets See All Microphone Cartridges See All Acoustic Calibrators See All Special Microphones See All Microphone Pre-amplifiers See All Sound Sources See All Accessories for acoustic transducers See All Experimental testing See All Transducer Manufacturing (OEM) See All Accessories See All Non-rotating (calibration) See All Rotating See All CCLD (IEPE) accelerometers See All Charge Accelerometers See All Impulse hammers / impedance heads See All Cables See All Accessories See All Electroacoustics See All Noise Source Identification See All Environmental Noise See All Sound Power and Sound Pressure See All Noise Certification See All Industrial Process Control See All Structural Health Monitoring See All Electrical Devices Testing See All Electrical Systems Testing See All Grid Testing See All High-Voltage Testing See All Vibration Testing with Electrodynamic Shakers See All Structural Dynamics See All Machine Analysis and Diagnostics See All Process Weighing See All Calibration Services for Transducers See All Calibration Services for Handheld Instruments See All Calibration Services for Instruments & DAQ See All On-Site Calibration See All Resources See All Software License Management

Weibull++ Reliability Growth - Simple MTBF Determination

logo of weibull
A new helicopter system is under development. System failure data are collected on five helicopters during the final test phase. The total number of flight hours is 500, accrued over a period of 12 weeks. The 500 flight hours are partitioned into six intervals, each covering a two-week period. Every two weeks, each helicopter undergoes a thorough inspection to uncover any failures that may have occurred since the last inspection. Therefore, although the actual failure times are unknown, the analysts have the cumulative total number of flight hours and the cumulative total number of failures for the five helicopters for each two-week period.
Interval #     Interval Length in Flight Hours     Failures in Interval
1 0 - 62 12
2 63-100 6
3 101 - 187 15
4 188 - 210 3
5 211 - 350 18
6 351 - 500 16

Analysis and discussion

 

A standard folio data sheet configured for grouped failure times data type is created by selecting Times-to-Failure Data > Grouped Failure Times on the first page of the Project Item Wizard window, as shown next.

Weibull Article - Selecting the data type and units of measurement for the new folio
Figure 1: Selecting the data type and units of measurement for the new folio

The data set is then entered and the Crow-AMSAA (NHPP) model is selected for analysis, as shown next.

Weibull Article - Data set entered in the standard folio
Figure 2: Data set entered in the standard folio

After analyzing the data, the results summary shows that the demonstrated failure intensity (DFI) value at the end of the 28 hours of testing is 4.4947.

Weibull Article - Summary of results showing that the failure intensity demonstrated at the end of the test
Figure 3: Summary of results showing that the failure intensity demonstrated at the end of the test

This can also be seen by using the Quick Calculation Pad (QCP). Since the test ended at 28 days, the DFI is equal to the instantaneous FI at 28 days, as shown next.

Weibull Article - Quick calculation showing the DFI (i.e., failure intensity at the end of the test)
Figure 4: Quick calculation showing the DFI (i.e., failure intensity at the end of the test)

A plot of the MTBF vs. time is shown next. The plot shows the mean time between failures plotted against time. The horizontal lines represent the instantaneous MTBF over the marked interval. The points represent actual failures in the data set.

Weibull Article - MTBF vs. time plot showing both instantaneous and cumulative MTBF
Figure 5: MTBF vs. time plot showing both instantaneous and cumulative MTBF

The cumulative MTBF line is then removed by right-clicking the plot.

Weibull Article - Show/Hide Items window with cleared option for cumulative MTBF line
Figure 6: Show/Hide Items window with cleared option for cumulative MTBF line

The plot now looks like this.

Weibull Article - MTBF vs. time plot showing only instantaneous MTBF
Figure 7: MTBF vs. time plot showing only instantaneous MTBF