See All Acoustic End-of-Line Test Systems See All DAQ and instruments See All Electroacoustics See All Software See All Transducers See All Vibration Testing Equipment See All Academy See All Resource Center See All Applications See All Industries See All Insights See All Services See All Support See All Our Business See All Our History See All Our Sustainability Commitment See All Global Presence
arrow_back_ios

Main Menu

See All Actuators See All Combustion Engines See All Durability See All eDrive See All Transmission & Gearboxes See All Turbo Charger See All DAQ Systems See All High Precision and Calibration Systems See All Industrial electronics See All Power Analyser See All S&V Hand-held devices See All S&V Signal conditioner See All Accessories See All DAQ Software See All Drivers & API See All nCode - Durability and Fatigue Analysis See All ReliaSoft - Reliability Analysis and Management See All Test Data Management See All Utility See All Vibration Control See All Acoustic See All Current / voltage See All Displacement See All Load Cells See All Pressure See All Strain Gauges See All Torque See All Vibration See All LDS Shaker Systems See All Power Amplifiers See All Vibration Controllers See All Accessories for Vibration Testing Equipment See All Training Courses See All Whitepapers See All Acoustics See All Asset & Process Monitoring See All Custom Sensors See All Data Acquisition & Analysis See All Durability & Fatigue See All Electric Power Testing See All NVH See All Reliability See All Smart Sensors See All Vibration See All Weighing See All Automotive & Ground Transportation See All Calibration See All Installation, Maintenance & Repair See All Support Brüel & Kjær See All Release Notes See All Compliance See All Our People
arrow_back_ios

Main Menu

See All CANHEAD See All GenHS See All LAN-XI See All MGCplus See All Optical Interrogators See All QuantumX See All SomatXR See All Fusion-LN See All Accessories See All Hand-held Software See All Accessories See All BK Connect / Pulse See All API See All Microphone Sets See All Microphone Cartridges See All Acoustic Calibrators See All Special Microphones See All Microphone Pre-amplifiers See All Sound Sources See All Accessories for acoustic transducers See All Experimental testing See All Transducer Manufacturing (OEM) See All Accessories See All Non-rotating (calibration) See All Rotating See All CCLD (IEPE) accelerometers See All Charge Accelerometers See All Impulse hammers / impedance heads See All Cables See All Accessories See All Electroacoustics See All Noise Source Identification See All Environmental Noise See All Sound Power and Sound Pressure See All Noise Certification See All Industrial Process Control See All Structural Health Monitoring See All Electrical Devices Testing See All Electrical Systems Testing See All Grid Testing See All High-Voltage Testing See All Vibration Testing with Electrodynamic Shakers See All Structural Dynamics See All Machine Analysis and Diagnostics See All Process Weighing See All Calibration Services for Transducers See All Calibration Services for Handheld Instruments See All Calibration Services for Instruments & DAQ See All On-Site Calibration See All Resources See All Software License Management

Upgrade for 2238 Mediator

Download this file to update your Mediator to the latest version. This upgrade is free of charge and only gives you access to the 2238 Meditator functionality you have already purchased. Contact your local Brüel & Kjær if you want to enhance the capabilities of your Type 2238.

 

Changelog 

NOTE: No change has been made to the calculation of any parameters. 

 

General changes (all software packages) 

  • Improved keyboard response 
  • More robust start-up procedure

 

Changes to Basic SLM Software BZ 7126 (version 1.1.0) 

  • The minimum preset measurement time is now 1 (one) second

 

Changes to Enhanced SLM Software BZ 7125 (version 1.1.0) 

  • There are now two ways of back-erasing: you either select the number of seconds to back-erase (as you know it), or you can select to back-erase a fixed interval whenever the pause key is pressed 
  • Addition September 2003 (version 1.1.1): Pre-set measurement time down to 1 s (from 30 s)

 

Changes to Logging SLM Software BZ 7124 

  • A misleading "file not saved" (when data are already safely stored) message has been corrected  
  • Taktmaximal Mittelungspegel (LAFTm5) added to the overall measurement results
  • Support for marker controlled sound recording with Version 4.0 and later of Noise Explorer 7815, Evaluator 7820/21 and Protector 7825

 

Installation process:

  • Click on the hyperlink below, download the file and unzip to a folder of your choice using Winzip (just double-click the downloaded file).At a convenient time you can upgrade your 2238 Mediator using the following steps:
  • Supply 2238 Mediator with fresh batteries
  • Connect Mediator to your PC's serial port using cable AO1442 (supplied with Mediator)
  • Run the file SETUP.EXE from the location chosen when you unzipped the file
  • Follow the on-screen instructions. Note: Your first choice will be for language of instruction – English, German, French, Spanish or Italian

 

NOTE: This program requires a  32-bit version of windows. If you are running a 64-bit version (e.g. Windows 7, 8 or 10) and do not have access to a PC with a 32-bit version of windows, you will need to use a 32-bit Virtual Machine.

 

Important information:

The program will automatically detect what is installed on your Mediator. If a newer version of any software is available you will be given the chance to upgrade it. If your 2238 Mediator is fully up-to-date, you will not be asked if you want to upgrade it; in this case simply exit the program. The option of installing a new application is only relevant if you have purchased new application software for your Mediator. In this case you will have received the upgrade software as well as a license code separately.