See All Acoustic End-of-Line Test Systems See All DAQ and instruments See All Electroacoustics See All Software See All Transducers See All Vibration Testing Equipment See All Academy See All Resource Center See All Applications See All Industries See All Insights See All Services See All Support See All Our Business See All Our History See All Our Sustainability Commitment See All Global Presence
arrow_back_ios

Main Menu

See All Actuators See All Combustion Engines See All Durability See All eDrive See All Production Testing Sensors See All Transmission & Gearboxes See All Turbo Charger See All DAQ Systems See All High Precision and Calibration Systems See All Industrial electronics See All Power Analyser See All S&V Hand-held devices See All S&V Signal conditioner See All Test Solutions See All DAQ Software See All Drivers & API See All nCode - Durability and Fatigue Analysis See All ReliaSoft - Reliability Analysis and Management See All Test Data Management See All Utility See All Vibration Control See All Acoustic See All Current / voltage See All Displacement See All Load Cells See All Pressure See All Strain Gauges See All Torque See All Vibration See All LDS Shaker Systems See All Power Amplifiers See All Vibration Controllers See All Accessories for Vibration Testing Equipment See All Training Courses See All Whitepapers See All Acoustics See All Asset & Process Monitoring See All Custom Sensors See All Data Acquisition & Analysis See All Durability & Fatigue See All Electric Power Testing See All NVH See All Reliability See All Smart Sensors See All Vibration See All Weighing See All Automotive & Ground Transportation See All Calibration See All Installation, Maintenance & Repair See All Support Brüel & Kjær See All Release Notes See All Compliance See All Our People
arrow_back_ios

Main Menu

See All CANHEAD See All GenHS See All LAN-XI See All MGCplus See All Optical Interrogators See All QuantumX See All SomatXR See All Accessories See All Accessories See All BK Connect / Pulse See All API See All Microphone Sets See All Microphone Cartridges See All Acoustic Calibrators See All Special Microphones See All Microphone Pre-amplifiers See All Sound Sources See All Accessories for acoustic transducers See All Experimental testing See All Transducer Manufacturing (OEM) See All Accessories See All Non-rotating (calibration) See All Rotating See All CCLD (IEPE) accelerometers See All Charge Accelerometers See All Impulse hammers / impedance heads See All Cables See All Accessories See All Electroacoustics See All Noise Source Identification See All Environmental Noise See All Sound Power and Sound Pressure See All Noise Certification See All Industrial Process Control See All Structural Health Monitoring See All Electrical Devices Testing See All Electrical Systems Testing See All Grid Testing See All High-Voltage Testing See All Vibration Testing with Electrodynamic Shakers See All Structural Dynamics See All Machine Analysis and Diagnostics See All Calibration Services for Transducers See All Calibration Services for Handheld Instruments See All Calibration Services for Instruments & DAQ See All On-Site Calibration See All Resources See All Software License Management

Aerodynamic noise is particularly important for passenger car driving comfort and high-speed train community comfort. At cruising and higher speeds, the aerodynamic noise is the dominant noise source in a car, so in relation to car interior aerodynamic noise, measurements are performed on full size vehicles in wind tunnels at different stages during development.

Finding the source of acoustic phenomena can be done in many ways, and is often depends on the conditions in which the phenomena occur. To investigate exterior aerodynamic noise produced by high-speed trains, wind tunnel measurements are typically performed on scale models of train sections or on components such as pantographs.

System Suggestion

Our PULSE Array-based Noise Source Identification Solutions can withstand the tough conditions of wind tunnels and still acquire reliable data. They include the two main methods for measurement on the exterior of vehicles in wind tunnels – near-field holography and beamforming.

With beamforming, the array is placed relatively far from the source, outside the turbulent airflow. For near-field holography a scanning method can be used where an array of measurement microphones has to be placed close to the vehicle under test, usually within the airflow region. Available hardware includes planar and half-wheel arrays and Surface Microphone Type 4949, designed for measurement of the true surface pressure, is exceptionally well-suited for mounting directly on the car surface during wind-tunnel testing.

Related Products

TYPE 4949

Surface Microphone For  Automotive Applications 

Automotive surface microphone designed for measurement of the true surface pressure. Ideal for mounting directly on the car surface during wind-tunnel tests and for measuring in confined spaces.

TYPE 4949-B

Automotive Surface Microphone

Automotive Surface Microphone with two coaxial cables and CIC, designed for measurement of the true surface pressure, especially in automotive applications. It is well-suited for mounting directly on the car surface during wind-tunnel tests or for easy measurement in confined spaces.

TYPE 8608 | PULSE

Acoustic beamforming software

Fast, single-measurement noise source location and mapping of moving and stationary objects, using a microphone array at a distance from the test object.

TYPES 8606, 8607, 8608

Options for holography and beamforming

Additional capabilities for our array acoustics noise source location and mapping software: Acoustic Beamforming Type 8608, Acoustic Holography Type 8607 and Spherical Beamforming Type 8606.